INSULATED WATER METER BOXES

Our insulating material has a density of 20 kg / m3. The following figures apply to the material
at  0 ºC, Which is the relevant temperature. The total insulating value is as follows:

Calculated only beneath the cover ( much better including the cover ).

Thermal conductivity: 0,032 W/m  ºC ( 0,35 W/m  ºC auf HDPE ).



_4,44 m2 x ºC_

          W

 

__0,22  x   W__

     m2  x  ºC

 
K 1: Cover


Insulating value =


K – value =

Corresponds to 173 mm. Mineral wool.

K 2: Conic ( average )

_2,06 m2 x ºC_

          W

 

__0,48  x  W__

      m2  x  ºC

 


Insulating value =


K – value =

Corresponds to 80 mm. Mineral wool.

_1,43 m2 x ºC_

          W

 

__0,70  x  W__

      m2  x  ºC

 
K 3: Vertical ( average )


Insulating value =


K – value =

Corresponds to 55 mm. Mineral wool.

________1______

  insulating value

 


K – value =


t = thickness

 ________1__________   

  thermal conductivity

 



Insulating value =